AquaComfort Heat Pump Error Codes & Troubleshooting

What Every Code Means and When to Call a Pro

Seeing a code on your AquaComfort heat pump? Pick your model or type your code below to see what it means, what to check first, and how urgent it is. We provide authorized service and warranty repair for AquaComfort.

No code on the display, or the code isn’t the problem? Use our pool heater troubleshooting guide.

✓ HVAC & EPA 608 Certified | ✓ 30+ Years Experience | ✓ 90-Day Workmanship Warranty

Doing a DIY repair? We can guide you over the phone.

Need a professional repair? We’ll fix it fast.

FREE to schedule. No obligation. No credit card needed

3 Things to Try Before Calling a Technician

Power-cycle

Turn off the heater, then the circuit breaker. Wait 5 minutes and restore power. For lockout codes (HP3, LP3, FL3), press any button on the control once.

Check water flow

Most codes (FLO, FL, LOW FLOW, HP, HPS) are caused by low water flow, not a broken part. Confirm the pump is on, the filter is clean, and all valves are open.

Check outside temp

Most heat pumps slow down or stop below about 50°F. LP, LPS and DEF can show up in cold weather. If they keep showing once it warms up, call us.

Disclaimer: This page is for informational purposes only. Heat pumps involve electricity, refrigerant, and moving parts, and internal repairs should always be done by a qualified technician. Warranty repairs on AquaComfort heaters must be approved by AquaComfort and done by an authorized technician. Improper service may void your warranty or cause injury.

Most Common AquaComfort Error Codes

These codes cover most AquaComfort service calls. The same problem can show a different code depending on your model, so each one lists the versions you might see. Don’t see your code? Find it by model below.

AquaComfort FLO Code: Low or No Water Flow (FLO, FL, FL3, LOW FLOW)

FLO means the heat pump isn’t getting enough water. The internal water pressure switch has opened and shut the heater off to protect the compressor. Vintage Signature models show FL, and Classic Black and Heat/Cool models show LOW FLOW. FL3 means it happened 3 times in an hour and the heater locked out.

  • Make sure the pool pump is on (check the timer).
  • Make sure the filter is clean and not in backwash.
  • Make sure all valves are open so water goes through the heater.

Once flow comes back, the heater restarts on its own. If it doesn’t, the water pressure switch may need adjusting or replacing.

Still showing FLO? Schedule a repair or call 407-786-0000.

AquaComfort HP Code: High Refrigerant Pressure (HP, HPS, HP3)

HP means the compressor’s high pressure switch has opened. On AquaComfort heaters, the usual cause is low water flow. Less often, the high-pressure switch itself has failed. HP3 means it tripped 3 times in an hour and the heater locked out.

  • Make sure the pool pump is on (check the timer).
  • Make sure the filter is clean and not in backwash.
  • Make sure all valves are open so water goes through the heater.

If HP3 comes back after you clear it, turn the heater off and call. Running it in a lockout loop strains the compressor.

Still showing HP? Schedule a repair or call 407-786-0000.

AquaComfort LP Code: Low Refrigerant Pressure (LP, LPS, LP3)

LP means the compressor’s low pressure switch has opened. Common causes are a dirty evaporator coil, a fan motor that isn’t running, cold outside air, or low refrigerant from a leak. LP3 means it tripped 3 times in an hour and the heater locked out.

  • Clear leaves and debris from around the coil.
  • Check that the fan on top is spinning when the heater runs.
  • Check the outside temperature.

If LP shows up on a warm day or keeps coming back, it’s often a refrigerant leak. Only an EPA 608 certified tech can test and recharge refrigerant, and our techs are certified.

Still showing LP? Schedule a repair or call 407-786-0000.

AquaComfort DEF and FS Codes: Defrost Cycle (DEF, FS, DEFROSTING)

DEF means the heater is defrosting its coil. In cold, damp weather, frost builds up on the evaporator coil, and the compressor pauses until it clears. Vintage Classic models show FS, and Classic Black and Heat/Cool models show DEFROSTING.

On Vintage Signature models, FS means something different: the flow switch is open in remote mode. Treat it like FLO and check your water flow.

If the heater stays in defrost for hours, or shows DEF on mild days, the defrost sensor or control may be failing.

Still showing DEF? Schedule a repair or call 407-786-0000.

AquaComfort Sensor Codes (tSO, tSS, ESO, ESS, PO, Pc, HC, dPO, dPC, do, De)

These mean the control board isn’t getting a good reading from a temperature sensor: either the water sensor or the evaporator (defrost) sensor.

  • Open codes (tSO, ESO, PO, dPO, do): a cut or loose wire, or a failed sensor.
  • Shorted codes (tSS, ESS, Pc, HC, dPC, De): shorted wiring, or a failed sensor.

Either way, the sensor usually needs to be tested and replaced, which is a quick repair for a tech.

Still showing a sensor code? Schedule a repair or call 407-786-0000.

AquaComfort Power and Control Codes (bo, SPi, PLE, CSE)

bo (Vintage Signature) means the control voltage has dropped below 18 volts, usually from low supply voltage to the heater. SPi (Vintage Classic) means the controller has failed. PLE or CSE means the control lost its saved settings.

Have a tech check bo and SPi before the heater runs again. If PLE or CSE keeps wiping your settings, the control board is failing.

Still showing one of these codes? Schedule a repair or call 407-786-0000.

Find your code below

Type your error code in the search box, or pick your model and tap your code.

We cover every AquaComfort line: 2023 Heat & Heat/Cool models, XL Series, Classic Black, Vintage Classic, Vintage Classic Heat/Cool, Vintage Signature, and the AquaChill chiller. Not sure which you have? The model number is on the label on the front panel.

Different brand? See pool heater error codes for every brand.

AquaComfort 2023 Heat & Heat/Cool Error Codes

All error codes for AquaComfort heat and heat/cool pool heat pumps (2023–present).

Models: ACT-750, ACT-1100, ACT-1250, ACT-1500, ACT-1750, ACT-1250 H/C, ACT-1750 H/C.

AquaComfort 2023 Heat & Heat/Cool Code Table

Code
What It Means
Likely Cause
What to do
FLO
Little or no water flow
Pump off, dirty or clogged filter, air leak, undersized pump, valves in the wrong position, filter in backwash, or a water pressure switch that needs adjusting or has failed
Call if it comes back
HP / HPS
Compressor high pressure
Low water flow to the heater, or a failed high-pressure switch
Call soon
HP3
High pressure lockout (3 trips in 1 hour)
The high pressure fault happened 3 times within an hour, so the heater locked itself out
Turn off & call now
LP / LPS
Compressor low pressure
Dirty evaporator coil, fan motor not running, low refrigerant, failed low-pressure switch, or cold outside air
Call soon
LP3
Low pressure lockout (3 trips in 1 hour)
The low pressure fault happened 3 times within an hour, so the heater locked itself out
Turn off & call now
tSO
Water temperature sensor open
Cut or loose sensor wiring, or a failed sensor
Call soon
tSS
Water temperature sensor shorted
Short in the sensor wiring, or a failed sensor
Call soon
ESO
Evaporator temperature sensor open
Cut or loose sensor wiring, or a failed sensor
Call soon
ESS
Evaporator temperature sensor shorted
Short in the sensor wiring, or a failed sensor
Call soon
DEF
Defrost cycle
Cold, damp air is frosting the evaporator coil and the heater is defrosting it
Call if it won't clear

AquaComfort code that won’t clear? We provide authorized service and warranty repair for AquaComfort.

FREE to schedule. No obligation. No credit card needed

AquaComfort XL Series Error Codes

All error codes for AquaComfort XL Series heat pump pool heaters (2013–present).

Models: ACT750, ACT1100, ACT1250, ACT1500, ACT1750 and their HC (heat/cool) versions.

AquaComfort XL Series Code Table

Code
What It Means
Likely Cause
What to do
FLO
Little or no water flow
Pump off, dirty or clogged filter, air leak, undersized pump, valves in the wrong position, filter in backwash, or a water pressure switch that needs adjusting or has failed
Call if it comes back
HP / HPS
Compressor high pressure
Low water flow to the heater, or a failed high-pressure switch
Call soon
HP3
High pressure lockout (3 trips in 1 hour)
The high pressure fault happened 3 times within an hour, so the heater locked itself out
Turn off & call now
LP / LPS
Compressor low pressure
Dirty evaporator coil, fan motor not running, low refrigerant, failed low-pressure switch, or cold outside air
Call soon
LP3
Low pressure lockout (3 trips in 1 hour)
The low pressure fault happened 3 times within an hour, so the heater locked itself out
Turn off & call now
tSO
Water temperature sensor open
Cut or loose sensor wiring, or a failed sensor
Call soon
tSS
Water temperature sensor shorted
Short in the sensor wiring, or a failed sensor
Call soon
ESO
Evaporator temperature sensor open
Cut or loose sensor wiring, or a failed sensor
Call soon
ESS
Evaporator temperature sensor shorted
Short in the sensor wiring, or a failed sensor
Call soon
DEF
Defrost cycle
Cold, damp air is frosting the evaporator coil and the heater is defrosting it
Call if it won't clear

AquaComfort XL showing a code? We provide authorized service and warranty repair for AquaComfort.

FREE to schedule. No obligation. No credit card needed

📄 Official AquaComfort manual: XL Series owner’s manual (PDF) · Back to model list ↑

AquaComfort Classic Black Error Codes

All display messages for AquaComfort Classic Black heat pump pool heaters (2011–2012). These models show words instead of short codes.

Models: ACT110, ACT125, ACT150, ACT165, ACT125HC, ACT165HC.

AquaComfort Classic Black Code Table

Code
What It Means
Likely Cause
What to do
Blank display
No power to the heater
Tripped breaker, blown fuse, or a failed control board
Call if it comes back
Low Flow
Little or no water flow
Pool pump off, a valve bypassing water around the heater, clogged line, filter or pump impeller, or a failed water pressure switch
Call if it comes back
Water Flow Lockout
Repeated low flow lockout
Restricted water flow from a dirty filter or a valve turned the wrong way
Call soon
Low Refrigerant Pressure
Low refrigerant pressure
Usually a refrigerant leak
Turn off & call now
Defrosting
Defrost cycle
Outside air is too cold for the heater to run; it restarts when the air warms up
Call if it won't clear
Even Heat Lockout
Even-heat feature lockout
Low or restricted water flow, or the unit is not wired for the even-heat feature
Call if it comes back
High Water Temperature
Water temperature too high
Control malfunction, or a second heat source (like solar) heating the water
Call soon
Evap Sensor Malfunction
Defrost (evaporator) sensor fault
Sensor failed or not connected
Call soon
Water Sensor Malfunction
Water temperature sensor fault
Sensor failed or not connected
Call soon
Solar Sensor Malfunction
Solar sensor fault (solar control only)
Solar sensor failed or not connected
Call soon

Classic Black acting up? We still repair these heaters and can get the parts they need. If yours is getting old, we’ll also tell you honestly whether replacement makes more sense.

FREE to schedule. No obligation. No credit card needed

AquaComfort Vintage Classic Error Codes

All error codes for AquaComfort Vintage Classic heat pump pool heaters (2003–2010).

Models: AC55, AC75, AC110, AC125, AC150.

AquaComfort Vintage Classic Code Table

Code
What It Means
Likely Cause
What to do
FLO
Little or no water flow
Pump off, dirty or clogged filter, air leak, undersized pump, valves in the wrong position, filter in backwash, or a water pressure switch that needs adjusting or has failed
Call if it comes back
FL3 / FLO3
Flow lockout, or filter mode left on
Shows after 3 flow faults in an hour, or when FIL mode is not set to OFF
Call soon
HP
Compressor high pressure
Low water flow to the heater, or a failed high-pressure switch
Call soon
HP3
High pressure lockout (3 trips in 1 hour)
The high pressure fault happened 3 times within an hour, so the heater locked itself out
Turn off & call now
LP
Compressor low pressure
Dirty evaporator coil, fan motor not running, low refrigerant, or a failed low-pressure switch
Call soon
LP3
Low pressure lockout (3 trips in 1 hour)
The low pressure fault happened 3 times within an hour, so the heater locked itself out
Turn off & call now
PO
Water temperature sensor open
Cut or loose sensor wiring, or a failed sensor
Call soon
Pc
Water temperature sensor shorted
Short in the sensor wiring, or a failed sensor
Call soon
dPO
Evaporator temperature sensor open
Cut or loose sensor wiring, or a failed sensor
Call soon
dPC
Evaporator temperature sensor shorted
Short in the sensor wiring, or a failed sensor
Call soon
FS
Defrost cycle
Cold, damp air is frosting the evaporator coil and the heater is defrosting it
Call if it won't clear
PLE / CSE
Control memory (EEPROM) data loss
The control lost its stored settings and needs to be reset to factory defaults
Call if it comes back
SPi
Control board fault
Failed controller
Call soon

Vintage Classic showing a code? We still repair these heaters and can get the parts they need. If yours is over 15 years old, we’ll also tell you honestly whether replacement makes more sense.

FREE to schedule. No obligation. No credit card needed

AquaComfort Vintage Classic Heat/Cool Error Codes

All display messages for AquaComfort Vintage Classic Heat/Cool heat pumps (2003–2010). These models show words instead of short codes.

AquaComfort Vintage Classic Heat/Cool Code Table

Code
What It Means
Likely Cause
What to do
LOW FLOW
Little or no water flow
Pump off, dirty or clogged filter, air leak, undersized pump, valves in the wrong position, filter in backwash, or a water pressure switch that needs adjusting or has failed
Call if it comes back
HIGH REFRIGERANT PRESSURE
Compressor high pressure
Low water flow to the heater, or a failed high-pressure switch
Call soon
3 HPS STRIKES LOCKOUT
High pressure lockout (3 trips in 1 hour)
The high pressure fault happened 3 times within an hour, so the heater locked itself out
Turn off & call now
LOW REFRIGERANT PRESSURE
Compressor low pressure
Dirty evaporator coil, fan motor not running, low refrigerant, or a failed low-pressure switch
Call soon
3 LPS STRIKES LOCKOUT
Low pressure lockout (3 trips in 1 hour)
The low pressure fault happened 3 times within an hour, so the heater locked itself out
Turn off & call now
EVAPORATOR SENSOR MALFUNCTION
Evaporator temperature sensor fault
Sensor wiring open, loose or shorted, or a failed sensor
Call soon
WATER SENSOR MALFUNCTION
Water temperature sensor fault
Sensor wiring open or shorted, or a failed sensor
Call soon
DEFROSTING / REVERSE CYCLE
Defrost cycle
Cold, damp air is frosting the evaporator coil and the heater is defrosting it
Call if it won't clear

Heat/Cool unit showing a message? We still repair these heaters and can get the parts they need. If yours is over 15 years old, we’ll also tell you honestly whether replacement makes more sense.

FREE to schedule. No obligation. No credit card needed

AquaComfort Vintage Signature Series Error Codes

All error codes for AquaComfort Vintage Signature Series heat pump pool heaters (2004–2012).

Models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750, MBP125, MBP175.

AquaComfort Vintage Signature Series Code Table

Code
What It Means
Likely Cause
What to do
FL
Internal flow switch open
Little or no water flow: pump off, dirty or clogged filter, air leak, undersized pump, valves in the wrong position, filter in backwash, or a water pressure switch that needs adjusting or has failed
Call if it comes back
FS
Internal flow switch open (remote mode)
Same causes as FL: little or no water flow while the heater is in remote mode
Call if it comes back
HP
High pressure switch open
Low water flow to the heater, or a failed high-pressure switch
Call soon
LP
Low pressure switch open
Dirty evaporator coil, fan motor not running, low refrigerant, or a failed low-pressure switch
Call soon
PO
Water thermistor open
Loose sensor wire, or a failed water thermistor
Call soon
HC
Water thermistor closed
Wire terminals touching, or a failed water thermistor
Call soon
do
Defrost sensor open
Loose sensor wire, or a failed defrost sensor
Call soon
De
Defrost sensor closed
Wire terminals touching, or a failed defrost sensor
Call soon
bo
Control voltage below 18VAC
Low supply voltage to the heater
Call soon

Signature Series showing a code? We still repair these heaters and can get the parts they need. If yours is over 15 years old, we’ll also tell you honestly whether replacement makes more sense.

FREE to schedule. No obligation. No credit card needed

AquaComfort AquaChill Chiller Error Codes

All error codes for the AquaComfort AquaChill pool chiller (2023–present).

Model: ACT-1750 C.

AquaComfort AquaChill Chiller Code Table

Code
What It Means
Likely Cause
What to do
FLO
Little or no water flow
Pump off, dirty or clogged filter, air leak, undersized pump, valves in the wrong position, filter in backwash, or a water pressure switch that needs adjusting or has failed
Call if it comes back
LP / LPS
Compressor low pressure
Low water flow to the chiller, low refrigerant, or a failed low-pressure switch
Call soon
LP3
Low pressure lockout (3 trips in 1 hour)
The low pressure fault happened 3 times within an hour, so the chiller locked itself out
Turn off & call now
HPS
Compressor high pressure
Condenser fan not running, dirty or blocked condenser coil, high refrigerant pressure, failed high-pressure switch, or very hot outside air
Call soon
HP3
High pressure lockout (3 trips in 1 hour)
The high pressure fault happened 3 times within an hour, so the chiller locked itself out
Turn off & call now
tSO
Water temperature sensor open
Cut or loose sensor wiring, or a failed sensor
Call soon
tSS
Water temperature sensor shorted
Short in the sensor wiring, or a failed sensor
Call soon
ESO
Evaporator temperature sensor open
Cut or loose sensor wiring, or a failed sensor
Call soon
ESS
Evaporator temperature sensor shorted
Short in the sensor wiring, or a failed sensor
Call soon
DEF
Defrost cycle
Water below about 38°F is frosting the coil and the chiller is defrosting it
Call if it won't clear

AquaChill not cooling? We provide authorized service and warranty repair for AquaComfort.

FREE to schedule. No obligation. No credit card needed

📄 Official AquaComfort manual: AquaChill owner’s manual (PDF) · Back to model list ↑

How to Reset an AquaComfort Heat Pump

Lockout codes (HP3, LP3, FL3, 3 HPS or 3 LPS STRIKES LOCKOUT): press any button on the control once. The heater locks itself out after the same fault happens 3 times in an hour.

Everything else:

  1. Turn the heater off at its control.
  2. Switch off the breaker.
  3. Wait 5 minutes.
  4. Turn the breaker back on, then the heater.

If the code comes back after a reset, the reset cleared the message but not the cause. Schedule a repair or call 407-786-0000.

When an Error Code Means You Need a Professional

Medallion Energy
Medallion Energy
Google star 1Google star 2Google star 3Google star 4Google star 5.0.7
4.781 Google reviews
Posted on Google Google
Carolyn Davis profile picture
Carolyn Davis
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
I highly recommend this company for Pool Heater repair. It took a little while for them to get out to see me because we are a couple hours away from them, however, once Moses Malone got to our house he went to work! He thoroughly diagnosed. step-by-step and figure out what was wrong with it and did not leave until it was finished. I am so happy!
Posted on Google Google
ScottZ profile picture
ScottZ
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Denise did a fantastic job helping isolate and identify an electrical issue. She worked directly with me throughout the troubleshooting process, demonstrating professionalism, patience, and a collaborative attitude as we checked various voltages. She provided logical explanations for the readings and offered a well-reasoned theory about the potential cause of the issue. Subsequent investigation confirmed that her speculations were correct. I was very impressed with her technical knowledge, methodical approach, and ability to work through the problem.
Posted on Google Google
Jeff Youmans profile picture
Jeff Youmans
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Google Review 5/5 Stars — Outstanding Service and Expert Guidance I cannot say enough good things about Medallion Energy. When I ran into an issue with my pool heat pump's control board, the owner, Jim Diroff, reached out to me personally to help work through it. Jim was extremely professional, courteous, and knowledgeable. He walked me step-by-step through troubleshooting the board, which helped us reach a clear conclusion: after 20+ years of faithful service, it was finally time to replace my old pool heater. Because of Jim's exceptional customer service, I am purchasing my new pool heater directly from Medallion Energy and having it shipped to Maryland. If you want honest advice, deep expertise, and a company that truly values its customers, look no further. Highly recommended!
Posted on Google Google
C Adams profile picture
C Adams
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
I want to thank Medallion Energy for helping me getting my heat pump working again. The display said "FLO" despite adequate water moving through the system and I was sure that it was the water pressure control switch that needed replacement. After reaching out to them via email they called me back and asked me what was going on. After explaining the issue they agreed that it was most likely the switch and shipped me a new one. It even came with directions on how to replace it. Once replaced I turned the heater on and it is working again. That saved me a huge bill to replace the heater. Thanks Medallion Energy for your help.
Posted on Google Google
Monika Trendell profile picture
Monika Trendell
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
AquaComfort stands behind their products and delivers exceptional service. My husband and I could not be more pleased with this company. The service team went above and beyond to fix our concerns even when the warranty was expired.
Posted on Google Google
Anthony Schiavi profile picture
Anthony Schiavi
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
I had the temperature sensor on my electric heater fail and I worked with tech support (Nikki) who did an excellent job assisting me in clearing a code to get the heater running despite the failing sensor and said she would ship out a new temp sensor with complete instructions to accomplish the repair (if I felt comfortable doing it) or send a repair technician. I opted to do the repair myself. Took less than an hour and the directions were spot on and easy to follow. My heater is back working and the new sensor performing like new. My heater was still under warranty so no cost to me.
Posted on Google Google
Mike Houck profile picture
Mike Houck
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Called the number and spoke to specialist Nikki. She is knowledgeable, professional and patient. She walked me through trouble shooting our pool heater and saved us alot of money. Ordered the parts and we'll be up and running soon. Thanks Nikki!
Posted on Google Google
Kristin Bickerton profile picture
Kristin Bickerton
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Unbelievable customer service. Had the pleasure of working with Denise. Got back to me in minutes and help trouble shoot problem over phone on a holiday weekend. Ordered me correct part and was delivered in under a week. Fantastic!
Read our Google Reviews

Why People Choose Us For AquaComfort Repairs

Need help? Call us at 407-786-0000 or visit our pool heater repair page to learn more

FAQs

What does FLO mean on an AquaComfort heat pump?

FLO means little or no water is flowing through the heater, so the water pressure switch shut it off to protect the compressor. Make sure the pump is on, the filter is clean and not in backwash, and all valves are open. The heater restarts on its own once flow returns. If it doesn’t, the pressure switch may need adjusting or replacing. Schedule a repair or call 407-786-0000.

It depends on your model. On Vintage Classic heaters (AC55–AC150), FS means the heater is in a defrost cycle. On Vintage Signature heaters (AC750–AC1750, MBP125, MBP175), FS means the flow switch is open in remote mode, so check your water flow like you would for FLO. Find your model above to be sure. Still showing FS? Schedule a repair or call 407-786-0000.

Almost certainly FL, the flow code on Vintage Signature heaters. A lowercase “l” looks like a “1” on the display. FL means the internal flow switch is open because little or no water is reaching the heater. See the FLO section above.

They’re lockout codes. HP3 means the high pressure fault happened 3 times within an hour, and LP3 means the low pressure fault did. The heater locks itself out to protect the compressor. Press any button on the control once to clear it. If it locks out again, turn the heater off and call. Schedule a repair or call 407-786-0000.

DEF means the heater is defrosting its evaporator coil. In cold, damp weather, frost builds up on the coil, and the compressor pauses until it clears. If the heater stays in defrost for hours, or shows DEF on mild days, the defrost sensor or control may be failing. Schedule a repair or call 407-786-0000.

For lockout codes (HP3, LP3, FL3), press any button on the control once. For other codes, turn the heater off at its control, switch off the breaker, wait 5 minutes, then turn the breaker and heater back on. If the code comes back, the cause is still there.

Yes. We provide authorized service and warranty repair for AquaComfort heat pumps. Warranty work has to be approved by AquaComfort before service, so have your model number, serial number, and installation date ready when you call 407-786-0000 or fill out a repair request.

The model number is on the label on the front panel, and the serial number is on the front left top of the unit. Models starting with AC or MBP are older Vintage units (2003–2012). Models starting with ACT are Classic Black (2011–2012), XL Series (2013–present), or 2023 models. Pick your model above to see its codes.

A few codes clear once you fix the cause, like turning the pool pump back on (FLO) or waiting out a defrost cycle (DEF). Most others, including sensor, refrigerant, voltage, and control codes, need a certified tech. Get free basic troubleshooting or call 407-786-0000 and we’ll tell you over the phone whether it needs a visit.

Is it time for a new pool heater?

If your AquaComfort heater is beyond repair, we can help. See our pool heater replacement options to find the right heat pump for your pool.

Still dealing with a broken pool heater?

You don’t have to. Certified technicians, fast reliable service, guaranteed repairs. Call or click to get started.

FREE to schedule. No obligation. No credit card required.